THE SUBSTRATE
SURFACE MUST BE DRY AND FREE OF DUST, LOOSE DEBRIS,
LATENCIES, SAND, DIRT, OIL, GREASE, BITUMINOUS COATINGS, PAINT
COATINGS, AND CHEMICAL CONTAMINATION.
-
A BLOWER IS
RECOMMENDED TO COMPLETELY DRY THE SURFACE. A PROPANE
TORCH MAY BE USED PROVIDED YOU USE THE PROPER SAFETY PRECAUTIONS.
CAUTION SHOULD BE TAKEN BECAUSE OF THE EXPLOSIVE GASES COMMONLY
ASSOCIATED WITH SANITARY MANHOLES.
-
ALL HYDROSTATIC
LEAKS MUST BE STOPPED BY USE OF AN APPROPRIATE WATER STOP MATERIAL.
STRONG PLUG MANUFACTURED BY THE STRONG COMPANY, INC. IS
RECOMMENDED.
-
AFTER
SANDBLASTING, BLAST THE SURFACE WITH CLEAN AIR TO REMOVE ANY LOOSE
SAND EMBEDDED INTO THE SUBSTRATE. AN ACETONE WET WIPE IS ALSO
RECOMMENDED.
-
SANDBLASTERS
SHOULD HAVE A MINIMUM RATING OF 70 CFM AND DUST FREE SILICA SAND IS
RECOMMENDED.
-
CURING TIMES ARE
BASED ON WEATHER CONDITIONS OF 70 DEGREES FAHRENHEIT AND 60%
RELATIVE HUMIDITY. CURING TIMES MAY CHANGE DRAMATICALLY DEPENDING ON
WEATHER CONDITIONS. FLEX-SEAL UTILITY SEALANT WILL NOT BOND
PROPERLY TO UNCURED CEMENTITIOUS PRODUCTS. FOR BEST RESULTS CONTACT
THE MANUFACTURE TO DETERMINE THE CURE TIME RELATED TO THE WEATHER
CONDITIONS YOU ARE WORKING IN.
-
OPENINGS OR GAPS
LARGER THAN 3/8” SHOULD BE PATCHED WITH SPRAY FOAM INSULATION, FOAM
WEATHER STRIPING, OR A QUICK SET CEMENT (WHEN USING A QUICK SET
CEMENT YOU MUST CONTACT THE MANUFACTURER TO DETERMINE THE TIME
REQUIRED FOR THE CEMENT TO COMPLETELY CURE).
-
IF COATING THE
SURFACE WITH A CEMENTITIOUS, EPOXY, OR FIBERGLASS MATERIAL DO NOT
PLACE ANY MATERIAL ONTO THE CASTING FRAME. THE FLEX-SEAL UTILITY
SEALANT WILL FORM THE BOND BETWEEN THE FRAME AND THE STRUCTURE.
-
FLEX-SEAL
UTILITY SEALANTâ
WILL NOT BOND TO ANY CEMENTITIOUS MATERIAL WITH A CHEMICAL
COMPOSITION THAT INCLUDES LATEX.
BITUMINOUS
COATINGS (CAST IRON)
REMOVE ALL
BITUMINOUS OR PAINT COATINGS WITH A *SANDBLASTER.
BRICK
CONSTRUCTED MANHOLES
MUST BE EITHER
ABRADED WITH A *SANDBLASTER TO CREATE AN ANCHOR PATTERN FOR THE
PRODUCT TO BOND TO OR PROFILED WITH A CEMENTITIOUS MATERIAL WE
RECOMMEND CHIMNEY PATCH & REPAIR (CPR) - MFG. SEALING SYSTEMS, INC
BUTYL
MASTIC
MUST BE REMOVED
COMPLETELY ANY TRACE OF BUTYL MASTIC WILL DESTROY THE FLEX-SEAL
MATERIAL. IF THE BUTYL MASTIC CANNOT BE REMOVED COMPLETELY IT MUST BE
COVERED WITH A CEMENT MATERIAL.
(CPR)
CHIMNEY PATCH & REPAIR - MFG. SEALING SYSTEMS, INC. (800-478-2054)
MUST BE ALLOWED TO
**CURE A MINIMUM OF 2 HOURS THEN SANDBLASTED.
CLAY PIPE
MUST BE ABRADED
WITH A *SANDBLASTER TO CREATE AN ANCHOR PATTERN FOR THE PRODUCT TO
BOND TO.
CONCRETE NEW
MUST CURE FOR
28 DAYS THEN IT SHOULD BE CLEANED WITH A SANDBLASTER REMOVING ANY
RELEASE AGENTS OR FORM OILS.
CONCRETE OLD
SHOULD BE
SANDBLASTED.
EMACO S88CA -
MFG. MASTER BUILDERS, INC.
MUST BE ALLOWED TO
**CURE A MINIMUM OF 7 DAYS THEN EITHER SANDBLASTED OR ETCHED
WITH A MURAT ACID/WATER SOLUTION 1:20 RATIO AND NEUTRALIZED WITH AN
AMMONIA/WATER SOLUTION 1:5 RATIO.
EPOXIES
SHOULD BE CLEANED
WITH A PRESSURE WASHER, THE SURFACE MUST BE DRIED THEN ABRADED WITH 40
GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL MANUFACTURED BY
SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED WITHIN 8 HOURS
AFTER THE APPLICATION OF NHNS.
FIBERGLASS
SHOULD BE CLEANED
WITH A PRESSURE WASHER, THE SURFACE MUST BE DRIED THEN ABRADED WITH 40
GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL MANUFACTURED BY
SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED WITHIN 8 HOURS
AFTER THE APPLICATION OF NHNS.
FOSROC - MFG.
FOSROC INC.
SHOULD BE CLEANED
WITH A PRESSURE WASHER, THE SURFACE MUST BE DRIED THEN ABRADED WITH 40
GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL MANUFACTURED BY
SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED WITHIN 8 HOURS
AFTER THE APPLICATION OF NHNS.
HIGH-BUILD -
MFG. PARSON ENVIRONMENTAL PRODUCTS, INC
DO NOT USE.
PRODUCT HAS DIFFICULT BONDING PROPERTIES.
HYDRO PLUG -
MFG. QUADEX INC.
DO NOT USE.
PRODUCT HAS DIFFICULT BONDING PROPERTIES.
MAINSTAY ML-72
- MFG. MADEWELL PRODUCTS CORP.
DO NOT USE.
PRODUCT HAS DIFFICULT BONDING PROPERTIES.
NBEC - MFG.
FIVE STAR PRODUCTS, INC.
MUST BE ALLOWED TO
**CURE A MINIMUM OF 24 HOURS. THEN SANDBLASTED.
MS-2A PORTLAND
CEMENT - MFG. STRONG SEAL SYSTEMS, INC. (800-982-8009)
MUST BE ALLOWED TO
**CURE A MINIMUM OF 4 DAYS THEN EITHER SANDBLASTED OR ETCHED
WITH A MURATIC ACID/WATER SOLUTION 1:20 RATIO AND NEUTRALIZED WITH AN
AMMONIA/WATER SOLUTION 1:5 RATIO. (NOTE: THIS PRODUCT IS SPRAY APPLIED
BY APPROVED STRONG SEAL SYSTEMS APPLICATORS)
MS-2C CALCIUM
ALUMINATE - MFG. STRONG SEAL SYSTEMS, INC (800-982-8009)
MUST BE ALLOWED TO
**CURE A MINIMUM OF 4 DAYS THEN EITHER SANDBLASTED OR ETCHED
WITH A MURATIC ACID/WATER SOLUTION 1:20 RATIO AND NEUTRALIZED WITH AN
AMMONIA/WATER SOLUTION 1:5 RATIO. (NOTE: THIS PRODUCT IS SPRAY APPLIED
BY APPROVED STRONG SEAL SYSTEMS APPLICATORS)
MULTI-PATCH -
MFG. PARSONS ENVIRONMENTAL PRODUCTS, INC
MUST BE ALLOWED TO
**CURE A MINIMUM OF 2 DAYS THEN SANDBLASTED.
PAINT COATINGS
REMOVE ALL PAINT
OR BITUMINOUS COATINGS WITH A SANDBLASTER.
PLANITOP X –
MFG. MAPEI
MUST BE ALLOWED TO
**CURE A MINIMUM OF 4 HOURS THEN SANDBLASTED.
PRECO PLUG -
MFG. FOSROC INC
MUST BE ALLOWED TO
**CURE A MINIMUM OF 4 DAYS THEN EITHER SANDBLASTED OR ETCHED
WITH A MURATIC ACID/WATER SOLUTION 1:20 RATIO AND NEUTRALIZED WITH AN
AMMONIA/WATER SOLUTION 1:5 RATIO.
PVC
SHOULD BE CLEANED
WITH A PRESSURE WASHER THE SURFACE MUST BE DRIED THEN ABRADED WITH 40
GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL MANUFACTURED BY
SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED WITHIN 8 HOURS
AFTER THE APPLICATION OF NHNS.
QM-1S RESTORE -
MFG. QUADEX INC
MUST BE ALLOWED TO
**CURE A MINIMUM OF 6 DAYS THEN EITHER SANDBLASTED OR ETCHED
WITH A MURATIC ACID/WATER SOLUTION 1:20 RATIO AND NEUTRALIZED WITH AN
AMMONIA/WATER SOLUTION 1:5 RATIO.
(QSR) QUICK SET
REPAIR - MFG. STRONG SEAL SYSTEMS, INC. (800-982-8009)
MUST BE ALLOWED TO
**CURE A MINIMUM OF 2 HOURS THEN SANDBLASTED.
QUICK PLUG -
MFG. PARSON ENVIRONMENTAL PRODUCTS, INC
DO NOT USE.
PRODUCT HAS DIFFICULT BONDING PROPERTIES.
RAVEN LINING
SYSTEMS
SHOULD BE CLEANED
WITH A PRESSURE WASHER, THEN THE SURFACE MUST BE DRIED THEN ABRADED
WITH 40 GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL
MANUFACTURED BY SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED
WITHIN 8 HOURS AFTER THE APPLICATION OF NHNS.
ROCKLAND COUNTY
SPECIAL MIX - MFG. ROCKLAND COUNTY SEWER DIST. #1
MUST BE ALLOWED TO
**CURE A MINIMUM OF 4 DAYS THEN SANDBLASTED.
SEWPERCOAT –
MGF. LaFARGE NORTH AMERICA, INC. (780-480-3600)
MUST BE ALLOWED
TO **CURE A MINIMUM OF 4 DAYS THEN SANDBLASTED.
SPEEDCRETE
BLUELINE – MFG. TAMMS INDUSTRIES. KIRKLAND, IL (815-522-3394)
DO NOT USE.
PRODUCT HAS DIFFICULT BONDING PROPERTIES.
SPEEDPAVE MP -
MFG. METALCRETE INDUSTRIES
DO NOT USE.
PRODUCT HAS DIFFICULT BONDING PROPERTIES.
SPRAY WALL
- MFG. SPRAYROQ, INC.
SHOULD BE CLEANED
WITH A PRESSURE WASHER, THE SURFACE MUST BE DRIED THEN ABRADED WITH 40
GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL MANUFACTURED BY
SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED WITHIN 8 HOURS
AFTER THE APPLICATION OF NHNS.
T-LOCK - MFG.
AMERON INTERNATIONAL
SHOULD BE CLEANED
WITH A PRESSURE WASHER, THE SURFACE MUST BE DRIED THEN ABRADED WITH 40
GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL MANUFACTURED BY
SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED WITHIN 8 HOURS
AFTER THE APPLICATION OF NHNS.
VERTAPAVE
CEMENT - MFG. METALCRETE INDUSTRIES
DO NOT USE.
PRODUCT HAS DIFFICULT BONDING PROPERTIES.
VYLON PIPE -
MFG. LAMSON INDUSTRIES
SHOULD BE CLEANED
WITH A PRESSURE WASHER, THE SURFACE MUST BE DRIED THEN ABRADED WITH 40
GRIT SAND PAPER AND COATED WITH NHNS PREP MATERIAL MANUFACTURED BY
SEALING SYSTEMS, INC. SSI PRODUCTS SHOULD BE APPLIED WITHIN 8 HOURS
AFTER THE APPLICATION OF NHNS.
For substrates not listed contact SSI to determine their compatibility
with SSI products.
REVISED 8/21/06
|