Go to Detail Specifications for
manhole sealing
1.1 Scope of Work
The work covered by this item includes but is not limited to
furnishing all labor, equipment, materials and supervision, and
performing all work necessary to seal the manhole as specified
herein. The work under this item includes the installation of
Flex-Seal Utility Sealant internal manhole sealing system and
accessories to the manhole through the frame joint area and the area
above the manhole cone, including all extensions to the chimney
area, as manufactured by Sealing Systems Inc., 9350 County Road 19, Loretto, MN. 55357
(800-478-2054) or an approved equal.
1.2 Area of Work
The work shall be performed in manholes as directed by the Owner’s
representative. The manhole sealing work will require an internal
seal to be installed. The internal manhole seal system may be required
to be installed in manholes without easements. The manhole sealing
shall be one of the first items of work and shall begin no later
then __________. The work shall progress continually until complete.
Work on this shall be done during warm and dry weather as per the
manufactures recommendation.
1.3 Internal Manhole Seals
(A) SEALS- manhole seal shall be
designed to prevent leakage of water into the manhole through the
frame joint area and the area above the manhole cone including all
extensions to the chimney area. Extensions shall include but is
not limited to lifting rings, brick and/or block material that may
have been used to achieve grade. The seal shall remain flexible
allowing for the repeated vertical or horizontal movements of the
frame due to frost lift, ground movement or the thermal movement
of pavements. The final liner material shall be made no less than
170 mils. of corrosion resistant aromatic flexible urethane
resin coating to be applied to the inside wall of the entire chimney
area as described above.
Mil thickness may vary depending on
the local climate. The contractor should contact the manufacture for
thickness recommendations.
The product shall have a minimum elongation
of 800% and a hardness (Durometer) of 75. Final liner shall have
a minimum tensile and adhesion strengths of 1150 psi and 175 lb.
l/in. respectively. The manhole sealing system shall conform to
the physical requirements of ASTM D- 412, with a minimum of 170 mils.
thickness for durability and resistance elongation and tearing.
The lining product shall have an aromatic urethane primer resin
on the complete surface. The sealing system shall line the interior
of the adjustment area from the cone/top of the manhole and onto
the inside of the casting. If the
manhole has been relined prior to the seal installation the seal
shall cover a minimum of 12 vertical inches or a minimum of 1 kit.
(B) INSTALLATION - All lose and protruding
mortar and brick that would interfere with the seal’s performance
shall be removed. Any lips for gravel pan supports shall be cut
off flush with casting. All sealing of any loose material or excessive
voids, patching cement, conforming to requirements by the manufacture.
Any patching cement work will require the contractor to contact
the sealant manufacture to determine in writing the proper time
required for the cement to completely cure prior to installing this
item. Preparation of the surface should include sandblasting
(minimum of 70CFM) and an acetone wet wipe to
ensure a clean surface as required by manufacture. Active leaks
(infiltration) should be corrected by a method approved by the Engineer
prior to installing an Internal Manhole Seal. The substrate surface must be free of sand, loose
debris, latencies, dust, oil, grease or chemical contamination.
A blower may be required to completely dry the substrate surface
or as recommended by manufacture. Flex-Seal Utility Sealant or approved
equal may require the proper mixing of agents, as recommended by
the manufacture’s instructions. Ensure casting and structure
surfaces are clean and dry where the primer is intended to adhere.
After allowing for proper drying of primer to occur, sealant may
be applied by brush as evenly as possible over the entire chimney
area, that includes the frame joint area and the area above the
manhole cone including all extensions to the chimney area. The contractor
is to furnish the Engineer (2) mirrors with extension handles that
can be used to inspect sealant application to areas underneath frame
without entry of manhole. These items will become the property of
the owner upon completion and at no additional cost of this item.
Cost for these items shall be included in the bid items for internal
manhole sealing work.
1.4 Training/Manufacture’s Certification
The manufacture must in writing certify that each of the contractor’s
representatives are approved to install Flex-Seal Utility Sealant
or approved equal for this item. The training shall be included
in the bid items for internal manhole seals. Contact the manufacture
for pricing 800-478-2054.
1.5 Submittals
The contractor shall submit shop drawings in accordance with the
General Contract Conditions. The manufacture’s specifications
for the materials and method for proposed installation of this item
shall be submitted to the Engineer for the approval before internal
sealing work commences.
1.6 Measurements and Payment
The work specified under this item shall be paid for the unit price
bid per manhole depending on the depth of each seal applied. The
depth of each seal will be recorded as the distance from the manhole
frame joint to the top joint of the manhole cone for which final
liner material is to be applied. Fractional measurement will be
rounded down to the nearest whole number as reported in inches (example;
payment for seal depth of 12-3/4 inches will be included with 12
inch distances). Payment will include all material and sealant system
accessories for this item. Payment for seals reported to be 12 inches
or less will be paid according to Pay Item No. _______. Payment
for seals reported to be greater then 12 inches will be paid according
to Pay Item No. _______. Payment under Item Nos. _____and_____shall
constitute payment in full for installing Internal Manhole Seals
by this method.
02-10-08
Flex-Seal Utility Sealant ® Detailed
Specification
Ready to print:
Flex-Seal Detailed Specification (PDF)

Flex-Seal Utility Sealant ®
Detailed Specification for a Cementitiously Lined Structure
Ready to print:
Flex-Seal Detailed Specification with Cementitious Liner (PDF)

Return to Top of Page
|