Infi-Shield Technical Data
APPLICATION STANDARDS & TECHNICAL DATA TEST
| Hardness |
D2240 |
60 +/-5 Duro |
61 Duro |
| Tensile |
D412 |
1200 PSI/Min |
1510 PSI/Min |
| Elongation |
D412 |
350 % Min |
460% |
| Ozone Resistance |
D1149 72 Hrs @ 50 PPHM |
No Cracks |
Pass |
Compression Set |
D395 Method B 22 Hrs @ 77Deg c |
25% Max |
24% |
| Heat Aged Hardness |
D573 70 Hrs @ 100Deg C |
No Requirements |
+65(+4 Pts) |
| Heat Aged Tensile |
D573 70 Hrs |
-15% Max |
-1390 Psi (-14%) |
Heat Aged Elongation |
D573 70 Hrs @ 100Deg C |
-20% Max |
370% (-20%) |
| Water Resistance |
D471 70 Hrs @ 100Deg C |
Volume Change +10% MAX |
+1.8% |
Low Temperature Brittleness |
D2137 —40Deg C |
No Crack On Impact |
Pass |
 |
The Infi-Shield® Uni-band has an inspection tab attached at the top of the seal and an aerosol primer is also included.
A clean surface is necessary but no special tools are required for installation. The Infi-Shield® Uni-band can be immediately
backfilled. |
|
|
|
|