Image
image
image
image


Infi-Shield Technical Data


APPLICATION STANDARDS & TECHNICAL DATA TEST
Property ASTM Test Method Requirements Test Results
Hardness D2240 60 +/-5 Duro 61 Duro
Tensile D412 1200 PSI/Min 1510 PSI/Min
Elongation D412 350 % Min 460%
Ozone Resistance D1149 72 Hrs @ 50 PPHM No Cracks Pass
Compression
Set
D395 Method
B 22 Hrs @ 77Deg c
25% Max 24%
Heat Aged Hardness D573 70 Hrs @ 100Deg C No Requirements +65(+4 Pts)
Heat Aged Tensile D573 70 Hrs -15% Max -1390 Psi (-14%)
Heat Aged
Elongation
D573 70 Hrs @ 100Deg C -20% Max 370% (-20%)
Water Resistance D471 70 Hrs @ 100Deg C Volume Change
+10% MAX
+1.8%
Low Temperature
Brittleness
D2137 —40Deg C No Crack On Impact Pass


Infi-Shield Technical Data The Infi-Shield® Uni-band has an inspection tab attached at the top of the seal and an aerosol primer is also included. A clean surface is necessary but no special tools are required for installation. The Infi-Shield® Uni-band can be immediately backfilled.